Using a higher percentage of argon can increase the weld metal’s tensile strength, but it provides no additional value and may increase the chances of weld cracking. Here’s why.

Posted: October 24, 2013

Figure 1. An example of FCAW-G welding. Using too much argon in the mix with any gas-shielded, flux-cored electrode can result in an excessive increase in puddle fluidity and the potential for an elevated weld-metal, tensile-strength level, which could potentially result in weld cracking issues.
Table 1. Deposition composition and mechanical properties results of a typical gas-shielded flux-cored wire designed for use with both CO2 and an Ar/CO2 blend.

Q: Our company recently switched our main flux-core wire to an E71T-12M-JH8 classification wire. It specifies to use only 75 percent – 80 percent argon (Ar) / balance carbon dioxide (CO2) shielding gas. We typically use a mix with 88 percent Ar. Is this not recommended? Or is this just one of those cases where we’ll need to do some testing on our own for verification?

A: There are two potential issues with using an 88 percent Ar / 12 percent CO2 shielding gas mix with the E71T-12M-JH8 electrode (aka wire). First, using that much argon in the mix with any gas-shielded, flux-cored electrode (see example in Figure 1) can result in an excessive increase in puddle fluidity. The second and greater potential issue, particularly with an American Welding Society (AWS; Miami, FL) “T-12” classified electrode, is an elevated weld-metal, tensile-strength level, which could potentially result in weld cracking issues.

Regarding the first issue, gas-shielded, flux-cored electrodes typically are used with either 100 percent CO2 shielding gas or an argon / CO2 mix (of which 75 percent Ar / 25 percent CO2 is the most common in the United States). The addition of argon to the CO2 increases the smoothness of the arc and operator appeal, particularly with out-of-position welding. It produces a smooth spray arc transfer and good puddle fluidity.

However, as the percentage of argon in the mix starts to surpass approximately 80 percent, the arc becomes more fluid and “soupy .” It can become more difficult to handle, particularly for vertical up and overhead welding. This is generally an operator appeal or personal preference issue.

Shielding gas can play a big role in the appearance of your weld and the cost of your project. Watch the video to find out why selecting the right gas for MIG welding matters.

As a side note, when using a mixed shielding gas for gas-shielded, flux-cored electrodes, generally the minimum percentage of argon to use with CO2 is 75 percent. As you decrease the percentage of argon in the mix below this level, you quickly start to lose the operator-appeal benefits of the argon. However, you still have to pay a premium for having argon in the gas mix. Many gas-shielded, flux-cored electrodes for use with mixed shielding gas will specify a recommended maximum percentage of argon, while the implied minimum level of argon is 75 percent.

Regarding the second issue, using more than the recommended percentage of argon in the mixed shielding gas can result in higher than expected weld-metal tensile strength.

First, note that per the AWS filler-metal specification, an AWS E71T-12M-JH8 classified electrode (i.e. “T-12” electrode) not only has a minimum tensile-strength requirement of 70,000 psi or 70 ksi (483 MPa), it also has a maximum tensile-strength requirement of 90,000 psi or 90 ksi (620 MPa). Electrodes with two other very common “T-1” and “T-9” classifications (e.g. E71T-1M / E71T-9M), have a minimum tensile-strength requirement of 70 ksi (483 MPa) and maximum tensile-strength requirement of 95 ksi (655 MPa).

Second, note the effect that each type of shielding gas has on the deposited weld-metal chemistry. CO2 is an active (i.e. reactive) gas. It will react with or “burn up” some of the alloy from the electrode in the arc, resulting in less alloy recovery in the weld metal. This results in a slight decrease in the weld metal’s yield and tensile strength.

On the other hand, argon is an inert (i.e. non-reactive) gas. It does not react with the alloys from the electrode in the arc. Therefore, the greater the percentage of argon in an Ar / CO2 shielding gas mix, the greater the alloy recovery from the electrode in the weld deposit. And the more alloy recovery in the weld deposit, the higher its resulting yield and tensile strengths.

This effect can be seen in the published literature of a “dual”-type gas-shielded, flux-cored electrode that is designed for use with both 100percent CO2 and an Ar/ CO2 mix. Table 1 shows the typical weld-deposit composition and mechanical properties of such an electrode. Note the differences, in particular, between manganese (Mn) and silicon (Si) levels, as well as yield and tensile strength between the weld deposits made using 100 percent CO2 shielding gas and those using 75 percent Ar / 25 percent CO2 shielding gas.

Manufacturers of gas-shielded, flux-cored electrodes carefully control the alloy levels in their products such that when used with their recommended percentages of argon in a mixed shielding gas, the resulting yield and tensile strengths of the weld metal will be within the electrode’s allowable minimum and maximum range.

However, if you use a higher percentage of argon than recommended, there will be more alloy recovery in the weld metal, resulting in higher strength levels. In general, as the weld metal’s tensile strength increases, it becomes less ductile (i.e. more rigid) and, therefore, more sensitive to cracking as the weldment cools. An additional preheating operation may then be necessary to help reduce the tendency for solidification cracking issues.

For a particular welding application, there may be no requirement for maximum weld strength. That decision is up to the design engineer for that particular welding application. However, in general, it is not recommended to exceed a gas-shielded, flux-cored electrode manufacturer’s recommendation for maximum percentage of argon used in the mixed shielding gas.

With the proper Ar/ CO2 shielding-gas mix, the electrode should produce a weld deposit with the specified minimum tensile strength. Using a higher percentage of argon, with a resulting increase in the weld metal’s tensile strength, provides no additional value. However, it may increase the chances of weld cracking issues. For your particular electrode, the recommendation would be to not use a shielding gas with more than 80 percent argon.

Subscribe to learn the latest in manufacturing.

Calendar & Events
Southeast Design – 2-Part Show
September 11 - 12, 2013
Greenville, SC
Mid-Atlantic Design – 2-Part Show
September 25 - 26, 2013
Phoenixville, PA
CMTS of Canada
September 30 - October 3, 2013
Mississauga, Canada
Wisconsin Manufacturing and Technology Show
October 8 - 10, 2013
Wisconsin State Fair Park Exposition Center Halls B&C
DISCOVER 2013
October 8 - 16, 2013
Florence, KY
WESTEC 2013
October 15 - 17, 2013
Los Angeles, CA
SOUTH-TEC
October 29 - 31, 2013
Greenville, SC
New England Design-2-Part Show
October 30 - 31, 2013
Marlborough, MA
DMG / Mori Seiki Manufacturing Days
November 12 - 15, 2013
Mori Seiki Manufacturing – Davis, CA
FABTECH
November 18 - 21, 2013
McCormick Place – Chicago, IL
Midwest Design-2-Part Show
November 20 - 21, 2013
Northern Kentucky Convention Center – Covington, KY
PCD Tool Manufacturing
November 20, 2013
United Grinding North America – Fredricksburg, VA